Particle Size Analyzer with Zeta Potential
Particle Size Analyzer with Zeta Potential
Korexan Co., Ltd. offers an advanced Particle Size Analyzer integrated with Zeta Potential measurement technology, designed for precise characterization of particles in liquid dispersions. Utilizing a combination of acoustic and electro-acoustic measurement techniques, the system enables simultaneous determination of particle size distribution and surface charge properties without the need for sample dilution. This ensures fast, accurate, and reliable analysis while preserving the original nature of even highly concentrated or opaque samples.
The instrument is suitable for a wide range of applications including nanoparticles, pharmaceuticals, emulsions, pigments, ceramics, and advanced material research. With its ability to measure multiple parameters such as zeta potential, pH, conductivity, and temperature in a single run, it provides comprehensive insight into dispersion stability and material behavior. The user-friendly software, automated analysis features, and robust design make it an ideal solution for research laboratories, quality control, and industrial process monitoring.
Capabilities
Key Features
Technical Data
Specifications
| Parameter | Value |
|---|---|
| Measurement Techniques | Acoustic Attenuation Spectroscopy & Electro-Acoustic (ESA) Method |
| Particle Size Range | 0.5 nm to 100 µm (model dependent) |
| Zeta Potential Range | ±450 mV |
| Mobility Range | ±18 µ·cm/V·s |
| Concentration Range | Up to 40% w/v (no dilution required) |
| Sample Type Compatibility | Aqueous and non-aqueous systems, including opaque and highly viscous samples |
| Additional Parameters Measured | pH, Conductivity, Temperature, Sound Attenuation & Velocity |
| Measurement Time | Typically less than 10 minutes per sample |
| Temperature Control | Integrated temperature monitoring with optional control system |
| Isoelectric Point (IEP) Determination | Automatic via potentiometric and volumetric titration |
| Sample Handling | Static, stirred, or pumped sample measurement capability |
| Calibration Requirement | Absolute measurement – no routine calibration with standards required |
| Power Supply | 220–240 V AC, 50/60 Hz |
| Operating Conditions | Laboratory environment, 15°C to 35°C, non-condensing humidity |
| Temperature control: 0degreeC to 120 degreeC | Laser: 658mm semi conductor Laser power 40mw |
| Size range: 0.3nm-15.0 microns | Minimum sample volume 1.5µl |
| Scattering angle: the Instrument measure particle size using forward scatter (Less Than 16 degrees) and side scatter angle (90 degrees) and back scatter Less than 176 degrees | Zeta potential range : >+/-1000mV |
| Mobility range: 10-11m2/v.S to 2x10-7m2/v.S | Size of particles measurable : 1.3nm to 100 microns |
| Transmittance: min sample volume-1.5µl Accuracy ±1% | Refractive index: 1.28 to 1.50, Accuracy ±0.5% |